Material: color steel ,FRP ,CFRT,plastic
Insulation Layer: Polyurethane foam or XPS, VIP
Hardware: 304 stainless steel
Material: color steel +Polyurethane foam
Outer box size: 1500*1000*1000 mm
Total volume: 951 L
Voltage: DC48V(45 Ah*4)
Temperature: -30℃
Structure: fiberglass+PU+fiberglass.
Panels thickness: 75-100mm
Insulation Layer: Polyurethane foam.
Hardware: 304 stainless steel
Temperature: –30℃
The main function of thermal insulation boards is to cut off the circulation of air and divide the compartment into different temperature sections. Based on different market demands, this product has five forms: BH001, BH002, BH003, BH004, and BH005.
Storage of Vaccines & Monitoring of Vaccine Fridge temperature • Vaccines must be stored in a Kingclimaceutical fridge • To comply with product licence, they must be – Stored within the temperature range of 2-80C – Stored in original packaging to protect from light & box contains batch details • Store on shelves, not touching the sides
Vaccine 25 (2007) 3980–3986 Freezing temperatures in the vaccine cold chain: A systematic literature review Dipika M. Matthiasa,∗, Joanie Robertsona,1, Michelle M. Garrisonb,2, Sophie Newlanda,1, Carib Nelsona,1 a PATH, 1455 NW Leary Way, Seattle, WA 98107, CHINA b Child Health Institute – University of Washington Box 3564920 Seattle, WA 98195, CHINA
02/03/2022 · Successful mass vaccination programmes are public health achievements of the contemporary world. While Kingclimaceutical companies are actively developing new vaccines, and demonstrating results of effectiveness and safety profiles, concerns on COVID-19 vaccine management are under-reported. We aimed to synthesise the evidence for efficient cold chain
freezer temperature form. If storing the vaccine in a refrigerator prior to use, use the refrigerator temperature form. If a cold chain break occurs fill out the. cold chain incident form (available as PDF and Excel) and fax it to your local public health unit. Equipment . The following equipment is required for receiving and storing the vaccine :
An effective cold chain relies on three main elements: A well-trained staff. Reliable storage and temperature monitoring equipment. Accurate vaccine inventory management. COLD CHAIN VACCINE STORAGE AND HANDLING Store In Freezer Between -50°C & -15°C (-58°F & +5°F) Store In Refrigerator Between 2°C & 8°C (36°F & 46°F) VAR£ Zostavax® £
23/11/2021 · Cold chain (storage, transport, Remove the box that holds the vial trays from the container. Do not open the vial trays or remove the vials until you are ready for thawing. ... Pfizer BioNTech ULTRA-FROZEN VACCINE Cold chain must be maintained during transport to another location.
8.6 Frozen ice packs MUST NOT be allowed to come into direct contact with vaccines. Insulation material must be New to separate vaccines from the frozen cool pack. 8.7 Any spaces within the cool box should be filled with insulating material. 8.8 The time that vaccines are exposed to room temperature during packing should be kept to a minimum.
Formula for determining number of doses supplied: Doses supplied= (Starting balance of viable doses + new doses received) – ending balance The formula for computing wastage factor based on defined wastage rate. is as follows: Wastage Factor (WF) = 100 100-WR Example: Assume that the wastage rate of a vaccine is 25%.
Use enough refrigerated or frozen packs to maintain the cold chain. Never put frozen packs near vaccines. Do not use loose or bagged ice. The number and placement of refrigerated or frozen packs inside the container will depend on container size, the ambient temperature, the volume of vaccine, and the duration of transport.
National Guidelines for Vaccine Storage and Distribution 3 The cold chain The ‘cold chain’ is defined in the Ministry of Health Immunisation Handbook 2011 as ‘the system of transporting and storing vaccines at +2˚C to +8˚C from the place of manufacture to the point of vaccine administration (the individual) ’. The Handbook
Vaccine is sent from the regional stores to district vaccine stores (n = 626), which, in turn, supply the last links in the chain: the primary or community health centres that act as peripheral vaccine stores (n = 1026 439). Note that, in terms of the cold chain, a region is
– Vaccine storage capacity: 20.7 liters (=7000 doses of measles vaccine) – Cold life without opening at 43°C: 129 hours • Can be New for vaccine storage at peripheral level when no refrigerator on the condition of renewing regularly the icepacks
03/11/2019 · Cold-chain storage is necessary to prevent damage to vaccines caNew by heat exposure. However, keeping vaccines too cold can be just as harmful as keeping them too warm, since many vaccines may be damaged by freezing. Freezing of vaccines can cause loss of potency which can never be restored. As a result, the vaccine’s
12.1 Cool box and ice packs/gel packs specifications 6 12.2 Cool Box Maintenance 7 12.3 Vaccine Storage and Monitoring 8 References: 11 APPENDICES 12 Appendix I: Membership of Development Group 13 Appendix II: Membership of Governance Group 13 Appendix III: Audit Tool - Cool Box 14 Appendix IV: Cold chain breaches and Light exposure 15
About 20–25 ice packs (8–10 kg of ice) and 35–40 ice packs (12–14 kg of ice) can be frozen in one day in small and large deep freezers, respectively. Standard ice packs New in UIP for cold box and vaccine KINGCLIMA are of 0.4 litre capacity.